What to do receiving the message "0x0126" when starting a drawing?


Last modified on: 2 de marzo de 2022

Problem:
AutoCAD LT has already been started 
Nordined LT is being started
As soon as Nordined LT asks to open a drawing file this errormassage is shown:

Fatal Error: Unhandled Access Violation Reading 0x0126 Exception at XXXXXXXXX


Cause:
This error message is shown because of a too short timeperiod for Nordined LT waiting for AutoCAD LT to be ready and responsive.

Solution:
When the Nordined LT application is started first and the choice is made to start with a new or existing drawing, from that moment AutoCAD LT is being started the errormessage will not be shown.

Alternative:

Attached to this article is the "Shared 10 sec.cadac"
  • Download this file to your dekstop
  • Rename the "Shared 10 sec.cadac" to "Shared 10 sec.reg"
  • Doubleclick the "Shared 10 sec.reg" 
  • When asked if the software is allowed to make changes click [ Yes ]
    With this file a value is added which grants more to for Nordined LT to wait for AutoCAD LT to be ready and responsive.