Revit Titleblock, values not filled - Revit
Last modified on: 29. April 2020
Problem:
The Titleblock loaded in the project is not being populated with the required information.
Cause:
The moment the Titleblock is not populated chances are the Titleblock's 'Shared Parameters' are not available in the new project.
Solution:
- Open a (new) project in which the projectparameters are present
For example the projecttemplate (Mostly creating a new project based on the companytemplate will suffice) - Return to the project where the projectparameters are not available
- Activatie Ribbontab 'Manage' and select the function ‘Transfer Project Standards’
- Select the newly opened project (based on the companytemplate)
- Click the 'Check None' box
- Only activate the 'Project Parameters' (Check the box)
- Click [ OK ]
Now the Titleblock can be filled.