Issue:

Users reported that even after manually changing the occurrence or file name, the browser node name kept reverting back to an unwanted name after using Rename Browser Nodes and selecting Default in Inventor.


Status:

This incident is being investigated by Autodesk for a possible cause and resolution.


Additional Information:

The part's browser node may have not been updated correctly last time it was used.


Workaround:

Change the browser name from the part, then the correct name will be shown in the assembly:

  1. Open an assembly and place the problematic part.
  2. The browser name is shown incorrectly.
  3. Open the part.
  4. Change its browser name to a dummy name such as abcdef.
  5. In the assembly, the browser name is shown as abcdef.
  6. In the part, change the browser name to a desired one.
  7. In the assembly, the browser name is now updated to the correct name.

After this, using Rename Browser Nodes and selecting Default will always show the correct name.

 

Source:

https://knowledge.autodesk.com/support/inventor/troubleshooting/caas/sfdcarticles/sfdcarticles/Browser-name-keeps-reverting-back-to-an-unwanted-name-when-using-Rename-Browser-Nodes-and-selecting-Default-in-Inventor.html 


Bij Cadac maken we onderscheid tussen Sales, Service & Support. Sales & Service vinden wij vanzelfsprekend. Wij helpen u met de aanschaf van uw product, dienst, training of expert en zorgen ervoor dat u probleemloos aan de slag kunt. Gratis en voor niets. U kunt zorgeloos met uw software starten, wij zorgen ervoor dat u het meeste uit uw software kunt halen.